Recommended measuring sets for resistivity & IP tomography

(Each set can be completed with any additional accessories at its listed price.)
1. Economy set with 48 line switch box (for 48 electrodes) - RES1-ECONOMY
ARES + 48 line switch box + 1 pair of connectors for user cables
ARES 850W Switch box Connectors

Configuration diagram (with user cables)                        Possible expansion Layout of MCC5 cable sections
Single channel system for use with own multielectrode cables (electrically compatible with ARES transmitter) allows performing basic 2D, 3D, borehole and static water level measurements.
2. Passive cable set with 48 electrodes - RES2-PASSIVE
ARES + 48 line switch box + 4 pcs of MCC5 passive cables (each with 12 outlets at 5 m spacing on the reel)
ARES 850 W Switch box Passive cable MCC5 4 pcs

Configuration diagram                                                                   Possible expansion Layout of MCC5 cable sections
Single channel system for 2D, 3D survey (with limited roll along ability).
3. Active cable set with 48 electrodes - RES3-ACTIVE
ARES + 6 pcs of MCS5 active cables (each with 8 outlets at 5 m spacing, 2 plastic transport boxes, each with 3 cables)
ARES 850 W Active cable MCS5 6 pcs Transport case 2 pcs

Configuration diagram                                                                                Possible expansion Layout of MCS5 cable sections
Single channel lightweight system for 2D, 3D survey with optimized current and potential lines and easy roll along possibility.
4. Advanced active cable set with 48 electrodes - RES4-AACTIVE
ARES II/1 + 6 pcs of MCS5/R active cables (each with 8 outlets at 5 m spacing, 2 plastic transport boxes, each with 3 cables)
ARES II/1 Active cable MCS5/R 6 pcs Transport case 2 pcs

Configuration diagram                                                                                 Possible expansion Layout of MCS5/R cable sections
Advanced single channel lightweight system for 2D, 3D, 4D survey with optimized current and potential lines and easy roll along possibility.
ARES II/1 main unit offers comfortable enhanced operation with graphic screen as well as possibility of upgrade to 10-channel system.
5. 5-channel advanced active cable set with 72 electrodes - RES5-5CH
ARES II/10 + 9 pcs of ME II/5-5 active cables (each with 8 outlets at 5 m spacing and section switch box, 3 plastic transport boxes, each with 3 cables)
ARES II/10 ME II/5-5 cable section 9 pcs Transport case 3 pcs

Configuration diagram                                                                                                                            Possible expansion Layout of ME II/5-5 cable sections
5-channel lightweight system for 2D, 3D, 4D survey on longer profiles and for advanced IP measurement equipped with optimized current and potential lines and easy roll along possibility. This set can be completed with next cable sections up to several hundreds of outlets in one cable line.
6. 10-channel advanced active cable set with 120 electrodes - RES6-10CH
ARES II/10 + 10 pcs of ME II/10-5 active cables (each with 12 outlets at 5 m spacing and section switch box on the reel)
ARES II/10 ME II/10-5 cable section 10 pcs

Configuration diagram                                                                                                               Possible expansion Layout of ME II/10-5 cable sections
Top performance 10-channel system for fast 2D, 3D, 4D survey on longer profiles and for advanced IP measurement equipped with optimized current and potential lines and easy roll along possibility. This set can be completed with next cable sections up to several hundreds of outlets in one cable line.
7. VES set - RES7-VES
ARES + VES cables (2 x 500 m current, 2 x 100 m potential on the reels)
ARES 850 W Reel with 500 m of cable for current electrode 2 pcs Reel with 100 m of cable for potential electrode 2 pcs
Simple set for VES (vertical electrical sounding).
8. Water set - RES8-WATER
ARES II/10 + Switch box II (10 channels, 48 lines)
ARES II/10 Switch box II

Configuration diagram (with special 24 line water cable) Layout of special ME II water cable
This set (completed with special water cables - not included in the set price) serves both for water level continuous measurement with GPS positioning and for borehole investigations (borehole-borehole, borehole-surface).
Example of special water cable on the reel (24 outlets at 2 m spacing, one end sealed, 10 m lead-in part, on the reel).
Water cable on reel


----