ARES II - AUTOMATIC RESISTIVITY SYSTEM


Overview Technical specifications Downloads

One ruggedized weatherproof unit integrates a powerful transmitter and a sensitive receiver completed with a rich software support for a variety of measuring methods.

Transmitter:

Power up to 850 W
Current up to 5.0 A
Current resolution 24 bits
Voltage 2000 Vp-p (actually applied voltage automatically optimizes the level of measured potential)
Protection full electronic protection

Receiver:

Number of channels 10 or 1
Input voltage range ±20 Vp-p
Voltage resolution 24 bits
Input impedance 20 MΩ
Mains frequency filtering 50 or 60 Hz selectable notch filter


Measuring methods:

  • 2D/3D/4D Multi-Electrode Resistivity and IP Tomography
  • VES - Vertical Electrical Sounding (resistivity and IP)
  • RP - Resistivity and IP Profiling
  • SP - Self Potential
  • Cross-Hole Tomography
  • Moving Applications with GPS

Supported arrays:

  • Wenner Alpha / Beta / Gamma, Wenner-Schlumberger, Dipole-Dipole, Pole-Dipole, Reverse Pole-Dipole, Pole-Pole, Equatorial Dipole-Dipole, Multiple Gradient Method, Cross-Hole, Borehole-Surface, user defined configurations

Measurement - features:

  • Checking of grounding
  • Automatic calibration
  • Automatic pulse cycling and checking of measured values
  • Easy interruption and continuing of the measurement
  • Capability of profile prolongation by means of multi-electrode cable rolling
  • Total accuracy:
    better than 1 % (typically)
  • IP - Induced Polarization (Chargeability):
    up to 20 adjustable IP-windows, each max. 30 s, step 20 / 16.66 ms
  • Pulse:
    0.2 s - 30 s, step 0.1 s
  • SP compensation:
    constant and linearly varying SP cancellation
  • Stacking:
    manual or automatic (with self-adaptive setting)
    adjustable optimum measured voltage and maximum acceptable measurement error
  • Stored values:
    position of the measured point, output current, input voltage, SP, apparent resistivity, standard deviation, chargeability with standard deviation for up to 20 IP windows
  • Number of electrodes:
    max. 65,000 in one array

Control unit

  • Easy-Control system with alphanumeric keyboard and graphic 4.7” high resolution LCD display
  • Easy real time horizontal and vertical data consistency checking and data remeasuring
  • Real time decay curve on display
  • Measuring system can be upgraded via Internet
  • Safety switch
  • Memory:
    256 MB, 100 files, more then 5 mil. readings
  • PC interface:
    USB
  • PC software:
    provides data download and export for processing programs (RES2DINV / RES3DINV, Surfer, IPI2WIN and others) as well as upload of measuring procedures
  • Power supply:
    12 V car battery, 12 V attachable battery pack, 12 V electronic power supply
    AC/DC adapter for office
  • Connectors:
    current and potential clamps, data download (USB and USB memory stick), GPS, battery
    and a universal one for all measuring accessories
  • Dimensions:
    15 x 21 x 40 cm
  • Weight:
    5.9 kg
  • Ambient conditions:
    -10°C to +60°C, weatherproof


----